TVS & Surge Clamp
Does this TVS survive the surge and keep the pin below its absolute maximum?
Could not save your rating. Try again.
هذه الصفحة غير مترجمة بالكامل بعد. الأجزاء غير المترجمة معروضة بالإنجليزية.
المدخلات
Series resistor and derating
النتائج
المعيار: VC' ≤ 0.9 × Vabs (design margin), failing above Vabs: 0.708 × your 30 V pin, with Rser 0 Ω
أظهر خطوات الحساب
- Dynamic resistance
R_dyn = (V_C − V_BR,max) / I_PP = (24.4 − 18.5) / 24.6 = 239.8 mΩ - Surge current
I = (V_s − V_BR,max) / (R_src + R_ser + R_dyn) = (500 − 18.5) / (42 + 0 + 0.2398) = 11.4 A - Clamp voltage at the pin
V_C' = V_BR,max + I × R_dyn = 18.5 + 11.4 × 0.2398 = 21.23 V - Current against the derated rating
I / (k_T × I_PP) = 11.4 / (1 × 24.6) = 11.4 / 24.6 = 0.463
VC' is at or below 27 V, 0.9 × Vabs, with no series resistance
كل النتائج (3)
at the peak of the surge
إلى أي حد نعرف هذا الرقم
- STMicroelectronics AN4275
- IEC 61000-4-5
- Texas Instruments SLVAE37
- IEC 61000-4-2
STMicroelectronics AN4275, IEC 61000-4-5 standard overview: the combination wave and its 2 Ω, 12 Ω and 42 Ω coupling paths المعادلة
IEC 61000-4-5, surge immunity test: the surge current shapes on the 12 Ω and 42 Ω coupling paths المعادلة
Texas Instruments SLVAE37, How to select a surge diode: match the rating pulse to the test pulse, or read the pulse-rating curve المعادلة
IEC 61000-4-2, electrostatic discharge immunity test: the contact-discharge current, 3.75 A/kV at the first peak and 2 A/kV at 30 ns, as summarised by the ESD Association المعادلة
يُقاس مقابل: The datasheet of your TVS: maximum breakdown and clamping voltages; peak pulse current and its rating pulse; the peak-pulse derating curve
A real clamp curve is not a straight line, and a real part usually sits below its datasheet maxima: its clamp is lower and its current slightly higher than shown. The maximum breakdown voltage sets most of the clamp at low surge currents, and the derating read off the part's own curve sets the current check. In ESD mode the clamp is an estimate only.
عملياً يهيمن على عدم اليقين مدخل واحد: Breakdown voltage, max. ضيّقه يضِق معه الجواب.
2 حالات في هذا الموقع تقارن هذه الحاسبة بأرقام حُسبت من دون كودها. اطّلع على الحساب.
هذه أداة مساعدة للتصميم. يبقى المهندس مسؤولاً عن التصميم وعن قراءة المرجع القياسي نفسه حيث يهم ذلك.
المسح البارامتري
غيّر مدخلاً واحداً على مدى، وشاهد الإجابة والحكم والهامش عند كل خطوة، جدولاً ومنحنى.Proأسوأ الحالات
أضف التفاوتات إلى المدخلات لتحصل على النطاق المضمون حول الإجابة الاسمية، لا الحالة النموذجية وحدها.ProCircuit
المبدأ
A TVS diode stays off below its breakdown voltage. Past it, it conducts and holds the line near its clamping voltage while the surge current flows through it to ground. This page models the surge generator as its open-circuit voltage behind its source resistance (IEC 61000-4-5), and the TVS as a straight clamp line through its two datasheet maxima. From them it finds the surge current and the voltage left at the protected pin, and checks the pin against its absolute maximum, the current against the TVS's derated pulse rating, and the stand-off against the line voltage.
- breakdown voltage, the datasheet maximum at its test current IT
- clamping voltage, the datasheet maximum at IPP
- peak pulse current, on the datasheet's rating pulse
- dynamic resistance, the slope of the clamp line
- surge current through the TVS
- voltage at the protected pin
- surge open-circuit peak voltage
- generator source resistance, by coupling path
- added series resistance between the source and the TVS
- pulse rating at TA, as a fraction of IPP
- ESD contact charge voltage
- ESD contact current at its first peak and at 30 ns
- target clamp, 0.9 × Vabs
- absolute maximum voltage of the protected pin
- TVS stand-off voltage; highest steady line voltage
تفاصيل إضافية
Stand-off first
In normal use the TVS must stay off. Its stand-off voltage VRWM, where the datasheet specifies the leakage IR, sits above the highest steady line voltage. 1.1 × Vline is this page's design margin.
Then the clamp and the current
On a low-voltage line there is little room between VBR,max and the pin's absolute maximum. The source resistance sets the current: 42 Ω on a signal line passes far less than 2 Ω across a power line. Added series resistance, a resistor or a PTC, lowers both the current and the clamp. It must be rated for the pulse.
The rating pulse
A datasheet states IPP on one pulse shape, often 10/1000 µs. The IEC 61000-4-5 surge is far shorter, and the part's pulse-rating curve allows a higher peak on a shorter pulse, so checking it against the 10/1000 µs rating is conservative.
Not modelled
The clamp's real curve between the two datasheet points, the change of VBR with temperature (the datasheet's temperature coefficient, where it gives one), the junction heating during the pulse, repeated pulses, the line's inductance and the protected pin's own clamp structure. For ESD the page gives the IEC 61000-4-2 currents and an estimate only.
إصدار المحرك 1.26.4