L-Network Impedance Matching
Which two stock parts match this antenna to 50 Ω, and what VSWR do they give across the band?
Could not save your rating. Try again.
هذه الصفحة غير مترجمة بالكامل بعد. الأجزاء غير المترجمة معروضة بالإنجليزية.
المدخلات
Part series
النتائج
المعيار: VSWR ≤ your 2:1 limit from 2.4 GHz to 2.4835 GHz, failing past 1.1 × it (design margin): worst 1.037:1 at 2.4835 GHz, with E24 parts
أظهر خطوات الحساب
- Node Q
Q = √(R_s / R_L − 1) = √(50 / 25 − 1) = 1.000 - Series part
X = −√(R_L (R_s − R_L)) − X_L = −√(25 × 25) + 15 = −10 Ω; C = 1 / (2π f |X|) = 1 / (2π × 2.44 GHz × 10 Ω) = 6.523 pF, nearest E24 6.8 pF - Shunt part
B = −√((R_s − R_L) / R_L) / R_s = −√(25 / 25) / 50 = −0.02 S; L = 1 / (2π f |B|) = 1 / (2π × 2.44 GHz × 0.02 S) = 3.261 nH, nearest E24 3.3 nH - Worst VSWR in band
VSWR = (1 + |Γ|) / (1 − |Γ|), largest of 101 points from 2.4 GHz to 2.4835 GHz = 1.037:1 at 2.4835 GHz
at 2.4835 GHz
كل النتائج (6)
before rounding to the series
(fhi − flo) / f
| Network | Exact parts | Stock parts | Worst VSWR |
|---|---|---|---|
| Series L at the load, shunt C, low-pass | 1.091:1 | ||
| Series C at the load, shunt L, high-pass | 1.037:1 |
إلى أي حد نعرف هذا الرقم
- D. M. Pozar
- C. Bowick
D. M. Pozar, Microwave Engineering المعادلة
C. Bowick, RF Circuit Design المعادلة
Real parts add loss, self-resonance and pad parasitics, and a real antenna moves across the band. The measured Z_L usually dominates, because it changes with the board, the ground clearance and the enclosure.
2 حالات في هذا الموقع تقارن هذه الحاسبة بأرقام حُسبت من دون كودها. اطّلع على الحساب.
هذه أداة مساعدة للتصميم. يبقى المهندس مسؤولاً عن التصميم وعن قراءة المرجع القياسي نفسه حيث يهم ذلك.
المسح البارامتري
غيّر مدخلاً واحداً على مدى، وشاهد الإجابة والحكم والهامش عند كل خطوة، جدولاً ومنحنى.Proأسوأ الحالات
أضف التفاوتات إلى المدخلات لتحصل على النطاق المضمون حول الإجابة الاسمية، لا الحالة النموذجية وحدها.ProCircuit
المبدأ
An L network is two reactive parts, one in series and one in shunt, that turn a load impedance into the source resistance at one frequency. This page finds every L network that matches ZL to Rs, rounds each part to a stock value, and checks the VSWR the stock parts give across your band. ZL is the load at f, as measured, held constant across the band.
- source resistance: the feed line, usually 50 Ω
- load impedance at f, its resistance and its reactance (negative is capacitive)
- series reactance of the network
- shunt susceptance of the network
- the load's resistance in parallel form
- node Q of the network
- angular frequency, 2πf
- input impedance the source sees
- reflection coefficient at the source
- voltage standing wave ratio
- return loss and mismatch loss, in dB
تفاصيل إضافية
Which networks exist
With the series part next to the load, a match exists when RL ≤ Rs. With the shunt part next to the load, it exists when the load's parallel resistance Rp is at least Rs. Both can hold, and each form has two signs, so a load has up to four L networks (Pozar). The page lists each one once.
Low-pass or high-pass
A series inductor with a shunt capacitor is low-pass, and also attenuates a transmitter's harmonics. A series capacitor with a shunt inductor is high-pass, and keeps DC off the load. Every load has one of each. The others use two capacitors or two inductors. Best is the network whose stock parts give the lowest worst VSWR in the band.
Bandwidth
An L network's Q is set by the two resistances it joins, so its bandwidth is not a free choice. Bowick gives three-part π and T networks for a Q of your own choosing.
Stock parts and the board
Rounding each part to its series moves the match off f, and the worst VSWR across the band shows what that costs. Below about 0.5 nH or 0.5 pF a part is comparable to its pads and a short trace, so the board sets the match as much as the part does. The 0.5 nH and 0.5 pF of the page's note are a design choice.
إصدار المحرك 1.26.4